












RLT Home Total Spectrum MINI - 72 LED, 7-Wavelength Panel
Seven wavelengths, and the density of each
- 72 LEDs across 7 wavelengths
- 98.7 mW/cm² at 6 inches
- ≈0.0 µT at 6 inches
- 0–5,000 Hz, adjustable
Choose options













Overview
72 LEDs across seven wavelengths from 480nm to 1064nm. Aluminium housing, 8.8 lbs, sized for the face, hands and single joints.
The smallest panel in the Total Spectrum range and the one to choose when the target is a specific area rather than the whole body. It ships with a stand and a door-hanging kit, so it can sit on a desk, hang on a door, or be held at a set distance.
Seven wavelengths, and the density of each
Most panels run two wavelengths, sometimes five. This one carries seven, and RLT publishes the proportion of the array given to each — which is the number that actually matters, since a wavelength present at 2% of the array behaves very differently from one at 20%.
- 480nm — blue, 6% of array
- 630nm — red, 19%
- 660nm — red, 19%
- 810nm — near-infrared, 19%
- 830nm — near-infrared, 14%
- 850nm — near-infrared, 9%
- 1064nm — infrared, 14%
The 480nm and 1064nm bands are the unusual ones. Very few home panels carry either.
Two irradiance figures, and why they differ
RLT publishes irradiance measured two ways, and the gap between them is large:
- 170 mW/cm² at 8 inches — measured with a solar power meter
- 98.7 mW/cm² at 6 inches — measured with a spectrometer
A solar power meter is calibrated for broad-spectrum sunlight and reads high on a narrow-band LED array. A spectrometer measures the actual bands. The lower figure is the one to compare against other brands, and it is worth knowing that many published irradiance numbers in this category come from solar meters without saying so. RLT publishing both, with the instrument named, is unusual.
Both figures are stated at a distance. An irradiance number without a distance attached cannot be compared to anything.
Flicker and EMF
No flicker — the array does not strobe, which matters if you sit in front of it regularly. EMF measures approximately 0.0 µT at 6 inches or greater, taken with a Cornet meter. RLT publishes third-party test images for both.
MINI or COMPACT
Both panels are built the same way and run identical wavelengths at identical densities. What changes is how much of you they cover at once.
| MINI — this panel | COMPACT | |
|---|---|---|
| LEDs | 72 | 216 |
| Intended area | Face, hands, single joints | Back, shoulders, legs |
| Device size | 11.8 × 11.4 × 2.6" | 30.3 × 11.8 × 2.6" |
| Weight | 8.8 lbs (4 kg) | 22 lbs (10 kg) |
| Irradiance at 6" (spectrometer) | 98.7 mW/cm² | 99.0 mW/cm² |
| Irradiance at 8" (solar meter) | 170 mW/cm² | 172 mW/cm² |
| Shipped weight | 13.2 lbs (6 kg) | 26.5 lbs (12 kg) |
Identical on both: all seven wavelengths at the same densities, 0–5,000 Hz pulsing, nine preset modes plus a custom mode with four independently adjustable channels, touch interface and remote, 30-degree beam angle, 100,000-hour LED life, AC 100–240V, aluminium housing, RoHS and CE certified, no flicker, ≈0.0 µT EMF at 6 inches or more.
Note the irradiance rows: 98.7 versus 99.0 at six inches is not a meaningful difference. The COMPACT is not a more intense panel — it is the same intensity spread across three times the LEDs and roughly three times the length. Choose on the size of the area you want to cover, not on power.
Specifications
- LEDs: 72
- Wavelengths: 480 / 630 / 660 / 810 / 830 / 850 / 1064nm
- Wavelength Densities: 6% / 19% / 19% / 19% / 14% / 9% / 14%
- Irradiance: 170 mW/cm² at 8" (solar power meter) · 98.7 mW/cm² at 6" (spectrometer)
- Beam Angle: 30 degrees
- Pulsing: 0–5,000 Hz, adjustable
- Modes: 9 presets plus a custom mode adjusting intensity and pulsing across 4 channels (red, blue, near-infrared, 1064nm) independently
- Controls: Touch interface and remote
- Flicker: None
- EMF: ≈0.0 µT at 6 inches or greater (Cornet meter)
- LED Lifespan: 100,000 hours
- Voltage: AC 100–240V
- Device Dimensions: 300 × 290 × 65 mm / 11.8" × 11.4" × 2.6"
- Device Weight: 4 kg / 8.8 lbs
- Shipped Dimensions: 380 × 375 × 180 mm / 15" × 15" × 7"
- Shipped Weight: 6 kg / 13.2 lbs
- Housing: Aluminium
- Certifications: RoHS, CE (Low Voltage Directive and Electromagnetic Compatibility Directive)
RoHS restricts hazardous materials in the build. The two CE certificates cover electrical safety and electromagnetic compatibility. These are manufacturing and safety standards — they are not FDA clearance and do not indicate a medical device.
What Is Included
- Total Spectrum MINI device
- Stand
- Remote control
- Protective reading glasses
- Blackout goggles
- Door hanging kit
- Power cable
- User manual
How to Use
Position the panel at the distance the irradiance figure is quoted for — six inches for the spectrometer number, eight for the solar meter number. Closer means a higher dose over a smaller area; further back covers more at lower intensity.
Sessions typically run 10 to 20 minutes. Use the supplied eye protection, particularly with the panel near face level. Do not look directly into the array.
Disclaimer
This product is intended for general wellness use only. It is not a medical device and is not intended to diagnose, treat, cure, or prevent any disease or medical condition. Consult a qualified healthcare provider before use if you are pregnant, photosensitive, take photosensitizing medication, or have an implanted device such as a pacemaker.
Seven wavelengths, and the density of each
SPECIFICATION
What you are buying.
-
72 LEDs across 7 wavelengths
480 / 630 / 660 / 810 / 830 / 850 / 1064nm, with the array density published for each band.
-
98.7 mW/cm² at 6 inches
Spectrometer figure. A solar power meter reads 170 mW/cm² at 8 inches on the same panel.
-
≈0.0 µT at 6 inches
Measured on a Cornet meter. Third-party test images published for both EMF and flicker.
-
0–5,000 Hz, adjustable
Nine presets plus a custom mode setting four channels independently.
-
11.8 × 11.4 × 2.6 in
8.8 lbs. Aluminium housing. Stand and door-hanging kit included.
-
RoHS and CE
Electrical safety and electromagnetic compatibility. These are manufacturing standards, not FDA clearance.
HOW A SESSION RUNS
A session, start to finish.
Position
Six inches for the spectrometer figure, eight for the solar meter figure. Closer concentrates the dose over a smaller area; further back covers more at lower intensity.
Set
Pick one of the nine presets, or use the custom mode to set intensity and pulsing across red, blue, near-infrared and 1064nm separately.
Run
Sessions typically run 10 to 20 minutes. Use the supplied eye protection, particularly with the panel near face level.









